3/2 , 5/2 Double Solenoid Namur Valve - DCC Series

Model Information
Type:

3X2 , 5X2

Design:

Spool with Cartridge Type

Media:

Compressed Air, Filtered & Lubricated

Working Pressure Range:

2 - 10 bar

Ambient/Medium Temperature:

5°- 60° C

Materials of Construction:

Aluminium, Nitrile, Brass, Polymer

Coil Information
Coil Width:

26 mm

Coil Bore:

10 mm

Voltage (V) + 10%:

AC (50Hz, 60Hz) - 24V, 110V, 230V DC 12V, 24V

Power Consumption:

AC-6W, DC-5W

Duty Cycle:

Continuous

Class of Insulation:

Class H

Type of Coil Protection:

IP65

  • Features
  • Pneumatic Circuit Diagram
  • Diagram & Dimension

Features

  • Cartridge Type design for Long life
  • Compact design
  • Manual Override
  • Single and Manifold Mounting
  • Low Power Consumption
  • Fast responce time at maximum 1500 cycle/ min
  • Lubrication not essential
  • Wide range of coil voltages
  • 20 Lacs Cycle tested

1 - Input, 2/4 - Output, 3/5 - Exhaust

Model Flow
(at 6 Bar)
Port Size Function Symbol
In Out Exh
DCC-K1RV1 1200 LPM ¼” ¼” ¼” Spring Return (NC) 3/2 Single Solenoid Valve With Spring Return (NC/NO) Uflow
1200 LPM ¼” ¼” ¼” Spring Return (NO) 3/2 Single Solenoid Valve With Spring Return (NC/NO) Uflow

Diagram & Dimension